RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3312036106 - Archived data from Tue, 11. August 2020 18:02:09 CEST


This is all the information about APD 3312036106. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3312036106
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B06
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 384.5 V
Dark current: 19.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 151
Position in Box: 32
EP1 batch: 178
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.866462 V     T = -25 °C: 349.5782562 V
Voltage for Gain 150: T = +20 °C: 392.6034643 V     T = -25 °C: 357.0114198 V
Voltage for Gain 200: T = +20 °C: 396.9145324 V     T = -25 °C: 361.1061901 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.69931804 V-1     T = -25 °C: 4.49206855 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.414790919 V-1     T = -25 °C: 9.701164206 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.86021404 V-1     T = -25 °C: 14.80087257 V-1
Break-through voltage: T = +20 °C: 411.9617245 V     T = -25 °C: 375.8795559 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:44 CET jreher Updated box and position via API.
11. Aug 2020 18:02:09 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:06 CEST jreher Updated APD location via API.
03. Feb 2020 14:24:22 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:16 CET jreher Updated APD location via API.
27. Nov 2019 19:55:32 CET jreher Updated APD location via API.
25. Nov 2019 17:22:50 CET jreher Updated box and position via API.
26. Sep 2019 15:32:33 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:56:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:20 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:30 CEST Tobias Imported from Hamamatsu datasheet.