RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3311036041 - Archived data from Tue, 11. August 2020 18:02:00 CEST


This is all the information about APD 3311036041. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3311036041
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G08
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 384.4 V
Dark current: 27.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 150
Position in Box: 37
EP1 batch: 176
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.7714031 V     T = -25 °C: 349.0094289 V
Voltage for Gain 150: T = +20 °C: 391.519594 V     T = -25 °C: 356.2525421 V
Voltage for Gain 200: T = +20 °C: 395.8104644 V     T = -25 °C: 360.3220117 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.741016194 V-1     T = -25 °C: 4.989710256 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.63925918 V-1     T = -25 °C: 9.422381481 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.06506164 V-1     T = -25 °C: 15.01057396 V-1
Break-through voltage: T = +20 °C: 410.664338 V     T = -25 °C: 374.8397301 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:37 CET jreher Updated box and position via API.
11. Aug 2020 18:02:00 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:02 CEST jreher Updated APD location via API.
03. Feb 2020 14:25:04 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:13 CET jreher Updated APD location via API.
27. Nov 2019 19:55:21 CET jreher Updated APD location via API.
25. Nov 2019 17:22:45 CET jreher Updated box and position via API.
26. Sep 2019 15:33:17 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:56:11 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:19 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:29 CEST Tobias Imported from Hamamatsu datasheet.