RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3311036033 - Archived data from Tue, 11. August 2020 18:01:59 CEST


This is all the information about APD 3311036033. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3311036033
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 380.8 V
Dark current: 24 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 150
Position in Box: 29
EP1 batch: 176
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2348266 V     T = -25 °C: 345.7311595 V
Voltage for Gain 150: T = +20 °C: 387.9914332 V     T = -25 °C: 352.9350953 V
Voltage for Gain 200: T = +20 °C: 392.338871 V     T = -25 °C: 356.9873772 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.590400118 V-1     T = -25 °C: 5.17067943 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.0085665 V-1     T = -25 °C: 9.747650152 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.95274478 V-1     T = -25 °C: 15.50611811 V-1
Break-through voltage: T = +20 °C: 407.2122413 V     T = -25 °C: 371.4101755 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:36 CET jreher Updated box and position via API.
11. Aug 2020 18:01:59 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:01 CEST jreher Updated APD location via API.
03. Feb 2020 14:25:03 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:11 CET jreher Updated APD location via API.
27. Nov 2019 19:55:20 CET jreher Updated APD location via API.
25. Nov 2019 17:22:45 CET jreher Updated box and position via API.
26. Sep 2019 15:33:17 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:56:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:18 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:29 CEST Tobias Imported from Hamamatsu datasheet.