RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3304035707 - Archived data from Tue, 11. August 2020 18:01:21 CEST


This is all the information about APD 3304035707. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3304035707
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 388.8 V
Dark current: 27.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 146
Position in Box: 24
EP1 batch: 170
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.9126902 V     T = -25 °C: 353.7056433 V
Voltage for Gain 150: T = +20 °C: 396.6881303 V     T = -25 °C: 360.9710625 V
Voltage for Gain 200: T = +20 °C: 401.0074057 V     T = -25 °C: 365.0449959 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.633146084 V-1     T = -25 °C: 4.910340442 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.203906822 V-1     T = -25 °C: 9.095910494 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.40543919 V-1     T = -25 °C: 16.1248619 V-1
Break-through voltage: T = +20 °C: 415.4936837 V     T = -25 °C: 379.4152584 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:07 CET jreher Updated box and position via API.
11. Aug 2020 18:01:21 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:43 CEST jreher Updated APD location via API.
28. Jan 2020 16:59:06 CET vwerner Updated APD batch assignment via API.
28. Jan 2020 16:50:39 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:48:57 CET jreher Updated APD location via API.
27. Nov 2019 19:54:37 CET jreher Updated APD location via API.
25. Nov 2019 17:22:26 CET jreher Updated box and position via API.
23. Sep 2019 17:21:00 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:55:39 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:11 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:25 CEST Tobias Imported from Hamamatsu datasheet.