RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3217035501 - Archived data from Wed, 21. April 2021 14:46:18 CEST


This is all the information about APD 3217035501. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3217035501
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G04
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.9 V
Dark current: 20.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 53
Position in Box: 47
EP1 batch: 166
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.4252777 V     T = -25 °C: 352.6746634 V
Voltage for Gain 150: T = +20 °C: 396.3060604 V     T = -25 °C: 360.2470102 V
Voltage for Gain 200: T = +20 °C: 400.6798449 V     T = -25 °C: 364.5069583 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.436220597 V-1     T = -25 °C: 4.596152468 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.702554865 V-1     T = -25 °C: 9.033024529 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.17739394 V-1     T = -25 °C: 15.84161544 V-1
Break-through voltage: T = +20 °C: 415.3675677 V     T = -25 °C: 379.3725442 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:19:02 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:15:34 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:46:18 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:46 CET jreher Updated box and position via API.
11. Aug 2020 18:01:07 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:32 CEST jreher Updated APD location via API.
28. Jan 2020 16:22:51 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:47 CET jreher Updated APD location via API.
27. Nov 2019 19:54:05 CET jreher Updated APD location via API.
25. Nov 2019 17:22:13 CET jreher Updated box and position via API.
23. Sep 2019 17:22:26 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:55:17 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:07 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:25 CEST Tobias Imported from Hamamatsu datasheet.