Subdetector specification:  
Serial: 3215035438
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.3 V
Dark current: 24.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 142
Position in Box: 31
EP1 batch: 165
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.0433959 V     T = -25 °C: 346.6850627 V
Voltage for Gain 150: T = +20 °C: 389.8816901 V     T = -25 °C: 353.9697299 V
Voltage for Gain 200: T = +20 °C: 394.2412976 V     T = -25 °C: 358.0668151 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.602645142 V-1     T = -25 °C: 4.747593757 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.10020252 V-1     T = -25 °C: 9.606933459 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.17099052 V-1     T = -25 °C: 15.31001033 V-1
Break-through voltage: T = +20 °C: 409.874885 V     T = -25 °C: 373.3266742 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:15:03 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:12:29 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:41 CET jreher Updated box and position via API.
11. Aug 2020 17:55:10 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:29 CEST jreher Updated APD location via API.
12. Dec 2019 14:40:11 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:45 CET jreher Updated APD location via API.
27. Nov 2019 19:53:56 CET jreher Updated APD location via API.
25. Nov 2019 17:22:11 CET jreher Updated box and position via API.
04. Oct 2019 11:19:19 CEST spankonin Updated APD batch assignment via API.
23. Sep 2019 17:22:54 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:55:14 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:06 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:25 CEST Tobias Imported from Hamamatsu datasheet.