RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3214035372 - Archived data from Tue, 11. August 2020 17:55:01 CEST


This is all the information about APD 3214035372. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3214035372
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 386.4 V
Dark current: 25.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 141
Position in Box: 38
EP1 batch: 163
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.7312665 V     T = -25 °C: 350.8687666 V
Voltage for Gain 150: T = +20 °C: 394.5520751 V     T = -25 °C: 358.3062637 V
Voltage for Gain 200: T = +20 °C: 398.8752291 V     T = -25 °C: 362.4930984 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.714159428 V-1     T = -25 °C: 4.935381894 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.524311468 V-1     T = -25 °C: 9.111934463 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.86685778 V-1     T = -25 °C: 16.19431756 V-1
Break-through voltage: T = +20 °C: 413.634939 V     T = -25 °C: 377.711721 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:39:42 CET oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:29 CEST jreher Updated box and position via API.
05. Feb 2021 11:06:33 CET jreher Updated box and position via API.
11. Aug 2020 17:55:01 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:25 CEST jreher Updated APD location via API.
12. Dec 2019 14:41:08 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:42 CET jreher Updated APD location via API.
27. Nov 2019 19:53:46 CET jreher Updated APD location via API.
25. Nov 2019 17:22:06 CET jreher Updated box and position via API.
20. Sep 2019 18:49:16 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:55:07 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:04 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:24 CEST Tobias Imported from Hamamatsu datasheet.