RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3212035306 - Archived data from Fri, 05. February 2021 11:06:26 CET


This is all the information about APD 3212035306. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3212035306
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.1 V
Dark current: 24.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 140
Position in Box: 43
EP1 batch: 162
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.0457163 V     T = -25 °C: 351.012196 V
Voltage for Gain 150: T = +20 °C: 394.8786894 V     T = -25 °C: 358.436229 V
Voltage for Gain 200: T = +20 °C: 399.2182011 V     T = -25 °C: 362.5958817 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.590443687 V-1     T = -25 °C: 4.898030101 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.156771279 V-1     T = -25 °C: 9.071566638 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.28386752 V-1     T = -25 °C: 16.06395256 V-1
Break-through voltage: T = +20 °C: 414.1462404 V     T = -25 °C: 377.4638915 V
   
Notes:


Version history

Time Author Change comment
19. Nov 2021 13:05:32 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:39 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:50 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:35 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:26 CET jreher Updated box and position via API.
11. Aug 2020 17:54:52 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:21 CEST jreher Updated APD location via API.
12. Dec 2019 14:41:55 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:38 CET jreher Updated APD location via API.
27. Nov 2019 19:53:35 CET jreher Updated APD location via API.
25. Nov 2019 17:22:02 CET jreher Updated box and position via API.
20. Sep 2019 18:48:50 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:59 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:03 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:23 CEST Tobias Imported from Hamamatsu datasheet.