RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3207035021 - Archived data from Tue, 11. August 2020 17:54:15 CEST


This is all the information about APD 3207035021. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3207035021
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.7 V
Dark current: 25.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 137
Position in Box: 15
EP1 batch: 156
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.8492363 V     T = -25 °C: 344.721532 V
Voltage for Gain 150: T = +20 °C: 387.659362 V     T = -25 °C: 351.9560348 V
Voltage for Gain 200: T = +20 °C: 391.9926208 V     T = -25 °C: 356.0234462 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.700322441 V-1     T = -25 °C: 4.766940093 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.385005588 V-1     T = -25 °C: 9.774525147 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.70453255 V-1     T = -25 °C: 15.57273641 V-1
Break-through voltage: T = +20 °C: 407.4573296 V     T = -25 °C: 371.0511689 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:58 CET jreher Updated box and position via API.
11. Aug 2020 17:54:15 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:04 CEST jreher Updated APD location via API.
09. Dec 2019 18:14:05 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:06:50 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:06:20 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:25 CET jreher Updated APD location via API.
27. Nov 2019 19:53:00 CET jreher Updated APD location via API.
25. Nov 2019 17:21:45 CET jreher Updated box and position via API.
20. Sep 2019 18:45:07 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:33 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:57 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:20 CEST Tobias Imported from Hamamatsu datasheet.