RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3207035011 - Archived data from Fri, 05. February 2021 11:05:57 CET


This is all the information about APD 3207035011. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3207035011
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.9 V
Dark current: 16.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 137
Position in Box: 6
EP1 batch: 156
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.2036092 V     T = -25 °C: 347.8598321 V
Voltage for Gain 150: T = +20 °C: 391.0244157 V     T = -25 °C: 355.1872522 V
Voltage for Gain 200: T = +20 °C: 395.3767905 V     T = -25 °C: 359.3126914 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.56296955 V-1     T = -25 °C: 5.046861001 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.055347413 V-1     T = -25 °C: 9.415259349 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.04406268 V-1     T = -25 °C: 14.89039459 V-1
Break-through voltage: T = +20 °C: 410.4460852 V     T = -25 °C: 374.2497216 V
   
Notes:


Version history

Time Author Change comment
16. Feb 2021 12:25:43 CET jreher Updated box and position via API.
15. Feb 2021 15:40:03 CET jreher Assigned to capsule by script
05. Feb 2021 11:05:57 CET jreher Updated box and position via API.
11. Aug 2020 17:54:14 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:04 CEST jreher Updated APD location via API.
09. Dec 2019 18:14:22 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:08:26 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:24 CET jreher Updated APD location via API.
27. Nov 2019 19:52:59 CET jreher Updated APD location via API.
25. Nov 2019 17:21:44 CET jreher Updated box and position via API.
20. Sep 2019 18:45:07 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:32 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:57 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:19 CEST Tobias Imported from Hamamatsu datasheet.