RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3202034787 - Archived data from Tue, 11. August 2020 17:54:12 CEST


This is all the information about APD 3202034787. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3202034787
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 402 V
Voltage for Gain 100 (T=+25°C): 373.5 V
Dark current: 19.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 132
Position in Box: 48
EP1 batch: 150
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 373.2874215 V     T = -25 °C: 338.8530347 V
Voltage for Gain 150: T = +20 °C: 381.0968335 V     T = -25 °C: 346.0432865 V
Voltage for Gain 200: T = +20 °C: 385.481922 V     T = -25 °C: 350.0988972 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.550361623 V-1     T = -25 °C: 5.127531633 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.844253761 V-1     T = -25 °C: 9.638355371 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.38893936 V-1     T = -25 °C: 15.38455369 V-1
Break-through voltage: T = +20 °C: 401.3116002 V     T = -25 °C: 365.2298474 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:26 CET jreher Updated box and position via API.
11. Aug 2020 17:54:12 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:47 CEST jreher Updated APD location via API.
09. Dec 2019 18:14:21 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:08:25 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:11 CET jreher Updated APD location via API.
27. Nov 2019 19:52:09 CET jreher Updated APD location via API.
25. Nov 2019 17:21:27 CET jreher Updated box and position via API.
17. Sep 2019 12:04:31 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:54:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:51 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:16 CEST Tobias Imported from Hamamatsu datasheet.