Subdetector specification:  
Serial: 3116034742
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.4 V
Dark current: 11.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 132
Position in Box: 21
EP1 batch: 149
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.0665954 V     T = -25 °C: 342.476038 V
Voltage for Gain 150: T = +20 °C: 384.8768216 V     T = -25 °C: 349.7303187 V
Voltage for Gain 200: T = +20 °C: 389.2362006 V     T = -25 °C: 353.8033757 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.635918373 V-1     T = -25 °C: 4.851935492 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.119852683 V-1     T = -25 °C: 9.939077964 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.19348493 V-1     T = -25 °C: 15.95447178 V-1
Break-through voltage: T = +20 °C: 404.5887268 V     T = -25 °C: 368.7902776 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 19:18:54 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:18 CET jreher Updated box and position via API.
05. Feb 2021 11:05:23 CET jreher Updated box and position via API.
11. Aug 2020 17:54:07 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:45 CEST jreher Updated APD location via API.
09. Dec 2019 18:15:30 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:09 CET jreher Updated APD location via API.
27. Nov 2019 19:52:07 CET jreher Updated APD location via API.
25. Nov 2019 17:21:24 CET jreher Updated box and position via API.
17. Sep 2019 12:08:20 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:53:57 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:50 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:15 CEST Tobias Imported from Hamamatsu datasheet.