RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3115034688 - Archived data from Tue, 11. August 2020 17:53:58 CEST


This is all the information about APD 3115034688. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3115034688
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376 V
Dark current: 16.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 131
Position in Box: 27
EP1 batch: 147
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.0300386 V     T = -25 °C: 341.8518827 V
Voltage for Gain 150: T = +20 °C: 383.8732389 V     T = -25 °C: 349.1490106 V
Voltage for Gain 200: T = +20 °C: 388.2646019 V     T = -25 °C: 353.3100675 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.608544689 V-1     T = -25 °C: 5.01398953 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.99530268 V-1     T = -25 °C: 9.48296703 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.82121724 V-1     T = -25 °C: 14.57357823 V-1
Break-through voltage: T = +20 °C: 404.2903984 V     T = -25 °C: 369.15048 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:16 CET jreher Updated box and position via API.
11. Aug 2020 17:53:58 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:40 CEST jreher Updated APD location via API.
09. Dec 2019 18:15:56 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:06 CET jreher Updated APD location via API.
27. Nov 2019 19:51:56 CET jreher Updated APD location via API.
25. Nov 2019 17:21:20 CET jreher Updated box and position via API.
17. Sep 2019 11:37:13 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:53:50 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:49 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:15 CEST Tobias Imported from Hamamatsu datasheet.