RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3115034684 - Archived data from Tue, 11. August 2020 17:53:58 CEST


This is all the information about APD 3115034684. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3115034684
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 375.2 V
Dark current: 17 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 131
Position in Box: 23
EP1 batch: 147
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.601538 V     T = -25 °C: 340.8187309 V
Voltage for Gain 150: T = +20 °C: 383.4068956 V     T = -25 °C: 348.0363415 V
Voltage for Gain 200: T = +20 °C: 387.7497513 V     T = -25 °C: 352.1076629 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.462745669 V-1     T = -25 °C: 5.101908106 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.65383579 V-1     T = -25 °C: 9.641805245 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.00071817 V-1     T = -25 °C: 15.32366673 V-1
Break-through voltage: T = +20 °C: 403.1606946 V     T = -25 °C: 367.0876041 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:55:03 CET oafedulidis Assigned to capsule by script
01. Dec 2021 12:56:24 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:05:16 CET jreher Updated box and position via API.
11. Aug 2020 17:53:58 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:40 CEST jreher Updated APD location via API.
09. Dec 2019 18:15:56 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:05 CET jreher Updated APD location via API.
27. Nov 2019 19:51:56 CET jreher Updated APD location via API.
25. Nov 2019 17:21:20 CET jreher Updated box and position via API.
17. Sep 2019 11:37:12 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:53:50 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:48 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:15 CEST Tobias Imported from Hamamatsu datasheet.