RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3113034637 - Archived data from Tue, 11. August 2020 18:00:59 CEST


This is all the information about APD 3113034637. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3113034637
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C04
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 374.8 V
Dark current: 16.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 130
Position in Box: 40
EP1 batch: 146
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 374.9353607 V     T = -25 °C: 340.563947 V
Voltage for Gain 150: T = +20 °C: 382.7901129 V     T = -25 °C: 347.7589726 V
Voltage for Gain 200: T = +20 °C: 387.1692476 V     T = -25 °C: 351.8053801 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.613789295 V-1     T = -25 °C: 4.847244671 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.122498978 V-1     T = -25 °C: 9.985854114 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.11862654 V-1     T = -25 °C: 15.90978097 V-1
Break-through voltage: T = +20 °C: 402.3642935 V     T = -25 °C: 366.4227454 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:10 CET jreher Updated box and position via API.
11. Aug 2020 18:00:59 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:37 CEST jreher Updated APD location via API.
28. Jan 2020 16:17:08 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:03 CET jreher Updated APD location via API.
27. Nov 2019 19:51:46 CET jreher Updated APD location via API.
25. Nov 2019 17:21:16 CET jreher Updated box and position via API.
03. Sep 2019 11:34:47 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:43 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:47 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:14 CEST Tobias Imported from Hamamatsu datasheet.