Show Hamamatsu Avalanche Photo Diode 3112034571 - Archived data from Tue, 11. August 2020 18:08:00 CEST
					This is all the information about APD 3112034571. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 3112034571 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | Bochum | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | C09 | 
| Break-through voltage: | 402 V | 
| Voltage for Gain 100 (T=+25°C): | 373.2 V | 
| Dark current: | 16.8 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 129 | 
| Position in Box: | 40 | 
| EP1 batch: | 145 | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | none | 
| Sent for analysis after irradiation: | none | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | none | 
| Dose used: | none | 
| Temperature: | none | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 402.6258 V T = -25 °C: 337.9566901 V | 
| Voltage for Gain 150: | T = +20 °C: 402.6258 V T = -25 °C: 345.3684672 V | 
| Voltage for Gain 200: | T = +20 °C: 402.6258 V T = -25 °C: 349.5564244 V | 
| Gain/Voltage slope at M = 100: | T = +20 °C: 756.0299955 V-1 T = -25 °C: 4.966107503 V-1 | 
| Gain/Voltage slope at M = 150: | T = +20 °C: 756.0299955 V-1 T = -25 °C: 9.077610634 V-1 | 
| Gain/Voltage slope at M = 200: | T = +20 °C: 756.0299955 V-1 T = -25 °C: 16.0557339 V-1 | 
| Break-through voltage: | T = +20 °C: 401.2902988 V T = -25 °C: 365.3355457 V | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 05. Feb 2021 11:05:03 CET | jreher | Updated box and position via API. | 
| 11. Aug 2020 18:08:00 CEST | jreher | Updated APD characteristics via API. | 
| 11. Aug 2020 17:50:32 CEST | jreher | Updated APD location via API. | 
| 06. Mar 2020 13:56:15 CET | spankonin | Updated APD batch assignment via API. | 
| 29. Nov 2019 11:47:59 CET | jreher | Updated APD location via API. | 
| 27. Nov 2019 19:51:35 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:21:12 CET | jreher | Updated box and position via API. | 
| 03. Sep 2019 11:34:25 CEST | spankonin | Updated APD batch assignment via API. | 
| 05. Jul 2019 13:53:35 CEST | jreher | Updated APD location via API. | 
| 03. Jan 2019 00:14:46 CET | Tobias | Corrected dark current unit. | 
| 14. Aug 2018 16:04:13 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					