RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3110034473 - Archived data from Tue, 11. August 2020 17:53:48 CEST


This is all the information about APD 3110034473. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3110034473
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G04
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 380 V
Dark current: 15.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 128
Position in Box: 24
EP1 batch: 142
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.5163793 V     T = -25 °C: 344.4836795 V
Voltage for Gain 150: T = +20 °C: 387.346522 V     T = -25 °C: 351.7939801 V
Voltage for Gain 200: T = +20 °C: 391.7072883 V     T = -25 °C: 355.912037 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.455104007 V-1     T = -25 °C: 4.787303765 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.632618873 V-1     T = -25 °C: 9.727388663 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.85742138 V-1     T = -25 °C: 15.39786771 V-1
Break-through voltage: T = +20 °C: 406.1600905 V     T = -25 °C: 370.6199305 V
   
Notes:


Version history

Time Author Change comment
15. Feb 2021 15:38:11 CET jreher Assigned to capsule by script
05. Feb 2021 11:04:53 CET jreher Updated box and position via API.
18. Dec 2020 13:59:52 CET jreher Updated box and position via API.
11. Aug 2020 17:53:48 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:26 CEST jreher Updated APD location via API.
09. Dec 2019 18:17:20 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:54 CET jreher Updated APD location via API.
27. Nov 2019 19:51:23 CET jreher Updated APD location via API.
25. Nov 2019 17:21:06 CET jreher Updated box and position via API.
03. Sep 2019 11:33:12 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:26 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:43 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:11 CEST Tobias Imported from Hamamatsu datasheet.