RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3107034345 - Archived data from Fri, 05. February 2021 11:04:40 CET


This is all the information about APD 3107034345. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3107034345
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D10
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.4 V
Dark current: 21.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 126
Position in Box: 38
EP1 batch: 140
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.7631472 V     T = -25 °C: 342.1168739 V
Voltage for Gain 150: T = +20 °C: 384.5524488 V     T = -25 °C: 349.3011734 V
Voltage for Gain 200: T = +20 °C: 388.8718283 V     T = -25 °C: 353.3404638 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.735447908 V-1     T = -25 °C: 5.010217844 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.558439271 V-1     T = -25 °C: 9.459932447 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.87708373 V-1     T = -25 °C: 15.02636854 V-1
Break-through voltage: T = +20 °C: 404.4167603 V     T = -25 °C: 368.3417773 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:32:05 CET oafedulidis Assigned to capsule by script
17. May 2021 09:15:17 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:40 CET jreher Updated box and position via API.
11. Aug 2020 17:53:30 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:19 CEST jreher Updated APD location via API.
09. Dec 2019 18:19:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:48 CET jreher Updated APD location via API.
27. Nov 2019 19:51:02 CET jreher Updated APD location via API.
25. Nov 2019 17:20:57 CET jreher Updated box and position via API.
03. Sep 2019 11:32:17 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:11 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:40 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:58 CEST Tobias Imported from Hamamatsu datasheet.