Show Hamamatsu Avalanche Photo Diode 3107034295 - Archived data from Thu, 03. January 2019 00:14:39 CET
					This is all the information about APD 3107034295. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 3107034295 | 
| Type: | Hamamatsu Avalanche Photo Diode | 
| Detector: | unassigned | 
| Unit: | unassigned | 
| Preamp: | 0 | 
| Current location: | unknown | 
| Installation information: | |
| Label: | none | 
| Manufacturer information: | |
| Wafer position: | E02 | 
| Break-through voltage: | 412 V | 
| Voltage for Gain 100 (T=+25°C): | 383.8 V | 
| Dark current: | 16.8 nA | 
| Screening Logistics: | |
| Available: | Yes | 
| Storage Box: | 419 | 
| Position in Box: | 44 | 
| EP1 batch: | none | 
| EP1 batch after irradiation: | none | 
| Shipment: | |
| Grid number: | none | 
| Position in grid: | none | 
| Arrival for irradiation: | none | 
| Sent for analysis after irradiation: | none | 
| Return for assembly: | none | 
| Irradiation: | |
| Date: | none | 
| Dose used: | none | 
| Temperature: | none | 
| Position: | none | 
| Bias voltage: | none | 
| Annealing: | |
| Date: | none | 
| Temperature: | none | 
| Duration: | none | 
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none | 
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none | 
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none | 
| Break-through voltage: | T = +20 °C: none T = -25 °C: none | 
| Notes: | 
						
					
Version history
| Time | Author | Change comment | 
|---|---|---|
| 16. Apr 2021 22:09:29 CEST | jreher | Updated APD characteristics via API. | 
| 16. Apr 2021 10:29:36 CEST | jreher | Updated APD location via API. | 
| 31. Mar 2021 14:15:17 CEST | jreher | Updated box and position via API. | 
| 26. Feb 2021 15:48:30 CET | jreher | Updated APD batch assignment via API. | 
| 05. Feb 2021 11:04:36 CET | jreher | Updated box and position via API. | 
| 03. Feb 2021 18:07:00 CET | jreher | Updated APD location via API. | 
| 28. Nov 2019 10:39:04 CET | jreher | Updated APD location via API. | 
| 27. Nov 2019 19:51:00 CET | jreher | Updated APD location via API. | 
| 25. Nov 2019 17:20:55 CET | jreher | Updated box and position via API. | 
| 05. Jul 2019 13:53:08 CEST | jreher | Updated APD location via API. | 
| 03. Jan 2019 00:14:39 CET | Tobias | Corrected dark current unit. | 
| 06. Jul 2018 22:38:58 CEST | Tobias | Imported from Hamamatsu datasheet. | 
 
						 
					