RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3106034252 - Archived data from Fri, 05. February 2021 11:04:30 CET


This is all the information about APD 3106034252. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3106034252
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.5 V
Dark current: 21.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 125
Position in Box: 17
EP1 batch: 137
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.2846752 V     T = -25 °C: 341.4363526 V
Voltage for Gain 150: T = +20 °C: 384.0682632 V     T = -25 °C: 348.6792841 V
Voltage for Gain 200: T = +20 °C: 388.4147934 V     T = -25 °C: 352.7398282 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.553118873 V-1     T = -25 °C: 4.88528305 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.971023477 V-1     T = -25 °C: 9.993834866 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.72217765 V-1     T = -25 °C: 16.03377237 V-1
Break-through voltage: T = +20 °C: 403.8716565 V     T = -25 °C: 367.8120353 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:09:42 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:28 CEST jreher Updated box and position via API.
05. Feb 2021 11:04:30 CET jreher Updated box and position via API.
11. Aug 2020 17:53:15 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:12 CEST jreher Updated APD location via API.
09. Dec 2019 18:20:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:42 CET jreher Updated APD location via API.
27. Nov 2019 19:50:50 CET jreher Updated APD location via API.
25. Nov 2019 17:20:51 CET jreher Updated box and position via API.
03. Sep 2019 11:31:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:01 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:38 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:57 CEST Tobias Imported from Hamamatsu datasheet.