RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3106034247 - Archived data from Tue, 11. August 2020 17:53:15 CEST


This is all the information about APD 3106034247. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3106034247
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A10
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 383.3 V
Dark current: 24.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 125
Position in Box: 13
EP1 batch: 137
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.6445781 V     T = -25 °C: 347.3962151 V
Voltage for Gain 150: T = +20 °C: 390.4204477 V     T = -25 °C: 354.7827945 V
Voltage for Gain 200: T = +20 °C: 394.7351185 V     T = -25 °C: 358.9217051 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.448885479 V-1     T = -25 °C: 4.813588755 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.80615486 V-1     T = -25 °C: 9.865820177 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.57114345 V-1     T = -25 °C: 15.749762 V-1
Break-through voltage: T = +20 °C: 406.8811199 V     T = -25 °C: 372.7307333 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:29 CET jreher Updated box and position via API.
11. Aug 2020 17:53:15 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:11 CEST jreher Updated APD location via API.
09. Dec 2019 18:20:00 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:42 CET jreher Updated APD location via API.
27. Nov 2019 19:50:49 CET jreher Updated APD location via API.
25. Nov 2019 17:20:50 CET jreher Updated box and position via API.
03. Sep 2019 11:31:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:38 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:57 CEST Tobias Imported from Hamamatsu datasheet.