Subdetector specification:  
Serial: 3105034204
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B12
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 384.5 V
Dark current: 21.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 124
Position in Box: 29
EP1 batch: 136
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.968199 V     T = -25 °C: 349.4621701 V
Voltage for Gain 150: T = +20 °C: 392.7764659 V     T = -25 °C: 356.8989632 V
Voltage for Gain 200: T = +20 °C: 397.1065975 V     T = -25 °C: 361.1039756 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.616286045 V-1     T = -25 °C: 4.707297434 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.17927033 V-1     T = -25 °C: 9.425043705 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.34372032 V-1     T = -25 °C: 14.68709548 V-1
Break-through voltage: T = +20 °C: 408.4321825 V     T = -25 °C: 375.0185655 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:23 CET jreher Updated box and position via API.
11. Aug 2020 18:07:49 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:09 CEST jreher Updated APD location via API.
06. Mar 2020 13:55:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:39 CET jreher Updated APD location via API.
27. Nov 2019 19:50:40 CET jreher Updated APD location via API.
25. Nov 2019 17:20:47 CET jreher Updated box and position via API.
30. Aug 2019 11:32:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:53 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:37 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:56 CEST Tobias Imported from Hamamatsu datasheet.