Subdetector specification:  
Serial: 3105034201
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C05
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 381.8 V
Dark current: 17.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 124
Position in Box: 26
EP1 batch: 136
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.1136476 V     T = -25 °C: 346.8924943 V
Voltage for Gain 150: T = +20 °C: 389.9076672 V     T = -25 °C: 354.1642529 V
Voltage for Gain 200: T = +20 °C: 394.2410124 V     T = -25 °C: 358.2529363 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.609013476 V-1     T = -25 °C: 5.015309118 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.137699126 V-1     T = -25 °C: 9.483165004 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.25973273 V-1     T = -25 °C: 14.96464348 V-1
Break-through voltage: T = +20 °C: 409.9261308 V     T = -25 °C: 373.5985472 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:24:17 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:14:52 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:23 CET jreher Updated box and position via API.
11. Aug 2020 18:07:49 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:08 CEST jreher Updated APD location via API.
06. Mar 2020 13:55:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:39 CET jreher Updated APD location via API.
27. Nov 2019 19:50:39 CET jreher Updated APD location via API.
25. Nov 2019 17:20:47 CET jreher Updated box and position via API.
30. Aug 2019 11:32:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:53 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:37 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:56 CEST Tobias Imported from Hamamatsu datasheet.