RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3104034124 - Archived data from Fri, 05. February 2021 11:04:16 CET


This is all the information about APD 3104034124. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3104034124
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 376.8 V
Dark current: 16.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 123
Position in Box: 29
EP1 batch: 135
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.3006888 V     T = -25 °C: 341.9566684 V
Voltage for Gain 150: T = +20 °C: 385.0133387 V     T = -25 °C: 349.1870129 V
Voltage for Gain 200: T = +20 °C: 389.3540091 V     T = -25 °C: 353.2619266 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.706716886 V-1     T = -25 °C: 5.061481158 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.961609358 V-1     T = -25 °C: 9.460531449 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.68559738 V-1     T = -25 °C: 15.01921003 V-1
Break-through voltage: T = +20 °C: 405.01363 V     T = -25 °C: 368.6486698 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:32:08 CET oafedulidis Assigned to capsule by script
17. May 2021 09:15:15 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:16 CET jreher Updated box and position via API.
11. Aug 2020 18:07:40 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:04 CEST jreher Updated APD location via API.
06. Mar 2020 13:54:40 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:36 CET jreher Updated APD location via API.
27. Nov 2019 19:50:29 CET jreher Updated APD location via API.
25. Nov 2019 17:20:42 CET jreher Updated box and position via API.
30. Aug 2019 11:31:25 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:46 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:35 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:55 CEST Tobias Imported from Hamamatsu datasheet.