RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3104034071 - Archived data from Fri, 05. February 2021 11:04:09 CET


This is all the information about APD 3104034071. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3104034071
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F12
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.8 V
Dark current: 16.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 122
Position in Box: 37
EP1 batch: 133
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.2647537 V     T = -25 °C: 346.2047175 V
Voltage for Gain 150: T = +20 °C: 389.0666477 V     T = -25 °C: 353.555373 V
Voltage for Gain 200: T = +20 °C: 393.4147452 V     T = -25 °C: 357.6725339 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.554407389 V-1     T = -25 °C: 4.874541893 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.013957688 V-1     T = -25 °C: 9.038511561 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.96760703 V-1     T = -25 °C: 16.01618978 V-1
Break-through voltage: T = +20 °C: 408.1406801 V     T = -25 °C: 372.3447176 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:41:10 CET oafedulidis Assigned to capsule by script
03. May 2021 15:20:07 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:09 CET jreher Updated box and position via API.
11. Aug 2020 18:00:49 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:00 CEST jreher Updated APD location via API.
28. Jan 2020 16:13:57 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:33 CET jreher Updated APD location via API.
27. Nov 2019 19:50:18 CET jreher Updated APD location via API.
25. Nov 2019 17:20:38 CET jreher Updated box and position via API.
30. Aug 2019 11:30:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:38 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:34 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:55 CEST Tobias Imported from Hamamatsu datasheet.