RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3104034069 - Archived data from Fri, 18. December 2020 14:00:05 CET


This is all the information about APD 3104034069. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3104034069
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.8 V
Dark current: 18.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 122
Position in Box: 35
EP1 batch: 133
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.0398674 V     T = -25 °C: 344.9222398 V
Voltage for Gain 150: T = +20 °C: 387.8307961 V     T = -25 °C: 352.2259218 V
Voltage for Gain 200: T = +20 °C: 392.1599789 V     T = -25 °C: 356.3357594 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.623228247 V-1     T = -25 °C: 5.026459934 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.19081451 V-1     T = -25 °C: 9.351061228 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.37666482 V-1     T = -25 °C: 14.80134075 V-1
Break-through voltage: T = +20 °C: 407.3234218 V     T = -25 °C: 371.2782801 V
   
Notes:


Version history

Time Author Change comment
15. Feb 2021 15:38:57 CET jreher Assigned to capsule by script
05. Feb 2021 11:04:09 CET jreher Updated box and position via API.
18. Dec 2020 14:00:05 CET jreher Updated box and position via API.
11. Aug 2020 18:00:48 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:00 CEST jreher Updated APD location via API.
28. Jan 2020 16:13:57 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:33 CET jreher Updated APD location via API.
27. Nov 2019 19:50:18 CET jreher Updated APD location via API.
25. Nov 2019 17:20:38 CET jreher Updated box and position via API.
30. Aug 2019 11:30:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:38 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:34 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:55 CEST Tobias Imported from Hamamatsu datasheet.