Show Hamamatsu Avalanche Photo Diode 3008033738 - Archived data from Tue, 11. August 2020 18:07:10 CEST


This is all the information about APD 3008033738. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3008033738
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.2 V
Dark current: 23.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 118
Position in Box: 23
EP1 batch: 126
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.1297725 V     T = -25 °C: 349.5879797 V
Voltage for Gain 150: T = +20 °C: 392.9431493 V     T = -25 °C: 356.9699151 V
Voltage for Gain 200: T = +20 °C: 397.2974983 V     T = -25 °C: 361.116015 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.585640112 V-1     T = -25 °C: 4.672454644 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.049403776 V-1     T = -25 °C: 9.520445103 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.07414611 V-1     T = -25 °C: 15.04127186 V-1
Break-through voltage: T = +20 °C: 412.6599503 V     T = -25 °C: 376.2988398 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:03:37 CET jreher Updated box and position via API.
11. Aug 2020 18:07:10 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:41 CEST jreher Updated APD location via API.
02. Mar 2020 16:21:36 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:47:17 CET jreher Updated APD location via API.
27. Nov 2019 19:49:33 CET jreher Updated APD location via API.
25. Nov 2019 17:20:18 CET jreher Updated box and position via API.
30. Aug 2019 11:28:11 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:52:05 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:27 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:51 CEST Tobias Imported from Hamamatsu datasheet.