RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3005033497 - Archived data from Tue, 16. February 2021 12:28:44 CET


This is all the information about APD 3005033497. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3005033497
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B06
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 382.5 V
Dark current: 17.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 115
Position in Box: 19
EP1 batch: 121
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.3534185 V     T = -25 °C: 347.9297364 V
Voltage for Gain 150: T = +20 °C: 391.1649889 V     T = -25 °C: 355.335511 V
Voltage for Gain 200: T = +20 °C: 395.5044013 V     T = -25 °C: 359.4987156 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.498622814 V-1     T = -25 °C: 4.91512532 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.843710327 V-1     T = -25 °C: 9.132988264 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.59342086 V-1     T = -25 °C: 16.19700006 V-1
Break-through voltage: T = +20 °C: 409.5776168 V     T = -25 °C: 373.515613 V
   
Notes:


Version history

Time Author Change comment
29. Apr 2021 17:03:51 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:44 CET jreher Updated box and position via API.
05. Feb 2021 11:03:13 CET jreher Updated box and position via API.
11. Aug 2020 18:06:49 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:27 CEST jreher Updated APD location via API.
25. Feb 2020 16:44:12 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:05 CET jreher Updated APD location via API.
27. Nov 2019 19:48:59 CET jreher Updated APD location via API.
25. Nov 2019 17:20:03 CET jreher Updated box and position via API.
27. Aug 2019 12:10:16 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:41 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:22 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:48 CEST Tobias Imported from Hamamatsu datasheet.