RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3003033376 - Archived data from Fri, 05. February 2021 11:02:58 CET


This is all the information about APD 3003033376. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3003033376
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.5 V
Dark current: 21.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 113
Position in Box: 22
EP1 batch: 119
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.9424028 V     T = -25 °C: 348.3259117 V
Voltage for Gain 150: T = +20 °C: 391.7833867 V     T = -25 °C: 355.7967065 V
Voltage for Gain 200: T = +20 °C: 396.1218874 V     T = -25 °C: 359.964784 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.654074485 V-1     T = -25 °C: 4.787972485 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.315302881 V-1     T = -25 °C: 9.736597709 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.6620747 V-1     T = -25 °C: 15.53781193 V-1
Break-through voltage: T = +20 °C: 410.8782698 V     T = -25 °C: 374.6686858 V
   
Notes:


Version history

Time Author Change comment
03. May 2021 10:26:23 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:02:58 CET jreher Updated box and position via API.
11. Aug 2020 18:06:32 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:19 CEST jreher Updated APD location via API.
25. Feb 2020 16:45:17 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:46:59 CET jreher Updated APD location via API.
27. Nov 2019 19:48:38 CET jreher Updated APD location via API.
25. Nov 2019 17:19:53 CET jreher Updated box and position via API.
27. Aug 2019 12:10:57 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:26 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:19 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:47 CEST Tobias Imported from Hamamatsu datasheet.