Serial: 3002033305
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D06
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387 V
Dark current: 19.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 112
Position in Box: 22
EP1 batch: 117
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.5668192 V     T = -25 °C: 351.4538976 V
Voltage for Gain 150: T = +20 °C: 395.3808646 V     T = -25 °C: 358.8767614 V
Voltage for Gain 200: T = +20 °C: 399.7041496 V     T = -25 °C: 363.0251308 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.424288661 V-1     T = -25 °C: 4.719467525 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.692746924 V-1     T = -25 °C: 9.563975833 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.25203073 V-1     T = -25 °C: 15.14645628 V-1
Break-through voltage: T = +20 °C: 414.7845705 V     T = -25 °C: 378.029629 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:50 CET jreher Updated box and position via API.
11. Aug 2020 17:46:45 CEST jreher Updated APD characteristics via API.
03. Dec 2019 15:03:11 CET jreher Updated APD location via API.
29. Nov 2019 11:46:54 CET jreher Updated APD location via API.
27. Nov 2019 19:48:26 CET jreher Updated APD location via API.
25. Nov 2019 17:19:47 CET jreher Updated box and position via API.
14. Nov 2019 17:31:22 CET spankonin Updated APD batch assignment via API.
27. Aug 2019 12:11:46 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:17 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:18 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:45 CEST Tobias Imported from Hamamatsu datasheet.