RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2904032710 - Archived data from Tue, 11. August 2020 18:00:22 CEST


This is all the information about APD 2904032710. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2904032710
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C01
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 384.9 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 109
Position in Box: 45
EP1 batch: 113
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.2636315 V     T = -25 °C: 349.3794238 V
Voltage for Gain 150: T = +20 °C: 392.2779168 V     T = -25 °C: 356.9149517 V
Voltage for Gain 200: T = +20 °C: 396.6839798 V     T = -25 °C: 361.2129345 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.198563918 V-1     T = -25 °C: 4.075757574 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.556647938 V-1     T = -25 °C: 9.188853287 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.82059344 V-1     T = -25 °C: 13.51613835 V-1
Break-through voltage: T = +20 °C: 411.793033 V     T = -25 °C: 376.1144368 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:02:28 CET jreher Updated box and position via API.
11. Aug 2020 18:00:22 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:11 CEST jreher Updated APD location via API.
28. Jan 2020 16:01:08 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:46:45 CET jreher Updated APD location via API.
28. Nov 2019 12:01:20 CET jreher Updated APD location via API.
25. Nov 2019 17:19:39 CET jreher Updated box and position via API.
23. Aug 2019 12:01:49 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:50:04 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:14 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:42 CEST Tobias Imported from Hamamatsu datasheet.