Serial: 2902032569
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.2 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 102
Position in Box: 44
EP1 batch: 100
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.203334 V     T = -25 °C: 344.0265626 V
Voltage for Gain 150: T = +20 °C: 387.0764176 V     T = -25 °C: 351.4371171 V
Voltage for Gain 200: T = +20 °C: 391.5060965 V     T = -25 °C: 355.5878404 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.570793989 V-1     T = -25 °C: 4.813298962 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.812094319 V-1     T = -25 °C: 8.970173255 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.38869757 V-1     T = -25 °C: 15.92054425 V-1
Break-through voltage: T = +20 °C: 407.6063075 V     T = -25 °C: 371.2534282 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:42:09 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:29:19 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:01:32 CET jreher Updated box and position via API.
11. Aug 2020 18:05:49 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:48:39 CEST jreher Updated APD location via API.
20. Feb 2020 15:16:06 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:46:18 CET jreher Updated APD location via API.
28. Nov 2019 12:01:12 CET jreher Updated APD location via API.
25. Nov 2019 17:19:05 CET jreher Updated box and position via API.
20. Aug 2019 12:47:58 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:56 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:10 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:38 CEST Tobias Imported from Hamamatsu datasheet.