Show Hamamatsu Avalanche Photo Diode 2904032748 - Archived data from Tue, 11. August 2020 18:05:14 CEST
This is all the information about APD 2904032748. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2904032748 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E14 |
| Break-through voltage: | 417 V |
| Voltage for Gain 100 (T=+25°C): | 388.4 V |
| Dark current: | 12.5 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 98 |
| Position in Box: | 45 |
| EP1 batch: | 94 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 388.0608694 V T = -25 °C: 352.6090973 V |
| Voltage for Gain 150: | T = +20 °C: 396.1189687 V T = -25 °C: 360.0828074 V |
| Voltage for Gain 200: | T = +20 °C: 400.5732383 V T = -25 °C: 364.287477 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.441418789 V-1 T = -25 °C: 4.624243073 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.609503447 V-1 T = -25 °C: 9.220072895 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 14.84985817 V-1 T = -25 °C: 14.38591654 V-1 |
| Break-through voltage: | T = +20 °C: 416.1236803 V T = -25 °C: 379.5986056 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 11:01:02 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 18:05:14 CEST | jreher | Updated APD characteristics via API. |
| 11. Aug 2020 17:55:32 CEST | jreher | Updated APD location via API. |
| 17. Feb 2020 17:49:59 CET | spankonin | Updated APD batch assignment via API. |
| 29. Nov 2019 11:50:59 CET | jreher | Updated APD location via API. |
| 27. Nov 2019 19:46:20 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:18:46 CET | jreher | Updated box and position via API. |
| 20. Aug 2019 12:44:50 CEST | jgrochowski | Updated APD batch assignment via API. |
| 05. Jul 2019 13:49:42 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:13:56 CET | Tobias | Corrected dark current unit. |
| 20. Jun 2018 13:36:21 CEST | Tobias | Imported from Hamamatsu datasheet. |