RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2817032138 - Archived data from Tue, 11. August 2020 18:04:58 CEST


This is all the information about APD 2817032138. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2817032138
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.7 V
Dark current: 9.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 15
EP1 batch: 92
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.9426502 V     T = -25 °C: 342.3390481 V
Voltage for Gain 150: T = +20 °C: 384.7263627 V     T = -25 °C: 349.734356 V
Voltage for Gain 200: T = +20 °C: 389.0557179 V     T = -25 °C: 353.8194076 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.678952901 V-1     T = -25 °C: 4.636258236 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.325076321 V-1     T = -25 °C: 9.924816513 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.58686782 V-1     T = -25 °C: 14.75609072 V-1
Break-through voltage: T = +20 °C: 405.8813981 V     T = -25 °C: 369.224747 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:51 CET jreher Updated box and position via API.
11. Aug 2020 18:04:58 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:24 CEST jreher Updated APD location via API.
17. Feb 2020 17:50:52 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:53 CET jreher Updated APD location via API.
27. Nov 2019 19:46:06 CET jreher Updated APD location via API.
25. Nov 2019 17:18:39 CET jreher Updated box and position via API.
23. Aug 2019 10:15:29 CEST spankonin Updated APD batch assignment via API.
20. Aug 2019 12:44:06 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:09 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:53 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:17 CEST Tobias Imported from Hamamatsu datasheet.