RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2817032117 - Archived data from Tue, 11. August 2020 18:04:56 CEST


This is all the information about APD 2817032117. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2817032117
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.8 V
Dark current: 6.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 97
Position in Box: 3
EP1 batch: 91
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.2899169 V     T = -25 °C: 343.9171463 V
Voltage for Gain 150: T = +20 °C: 387.0660292 V     T = -25 °C: 351.2007074 V
Voltage for Gain 200: T = +20 °C: 391.4104264 V     T = -25 °C: 355.2887524 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.533432391 V-1     T = -25 °C: 5.02942863 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.990629841 V-1     T = -25 °C: 9.409250408 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.93691285 V-1     T = -25 °C: 14.89783541 V-1
Break-through voltage: T = +20 °C: 405.9424312 V     T = -25 °C: 369.7551365 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:53:45 CET oafedulidis Assigned to capsule by script
16. Dec 2021 13:41:47 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:00:49 CET jreher Updated box and position via API.
11. Aug 2020 18:04:56 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:23 CEST jreher Updated APD location via API.
17. Feb 2020 17:52:56 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:52 CET jreher Updated APD location via API.
27. Nov 2019 19:46:05 CET jreher Updated APD location via API.
25. Nov 2019 17:18:38 CET jreher Updated box and position via API.
20. Aug 2019 12:40:48 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:08 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:53 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:17 CEST Tobias Imported from Hamamatsu datasheet.