Serial: 2816032098
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 386.2 V
Dark current: 19.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 96
Position in Box: 48
EP1 batch: 91
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.932938 V     T = -25 °C: 350.8953396 V
Voltage for Gain 150: T = +20 °C: 393.7305333 V     T = -25 °C: 358.5340397 V
Voltage for Gain 200: T = +20 °C: 398.0546032 V     T = -25 °C: 362.5656345 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.634270381 V-1     T = -25 °C: 4.997402084 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.282706687 V-1     T = -25 °C: 10.69385861 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.48384597 V-1     T = -25 °C: 17.3825331 V-1
Break-through voltage: T = +20 °C: 413.92312 V     T = -25 °C: 377.5898674 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:00:47 CET jreher Updated box and position via API.
11. Aug 2020 17:59:31 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:23 CEST jreher Updated APD location via API.
28. Jan 2020 14:54:09 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:51 CET jreher Updated APD location via API.
27. Nov 2019 19:45:57 CET jreher Updated APD location via API.
25. Nov 2019 17:18:37 CET jreher Updated box and position via API.
20. Aug 2019 12:40:48 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:03 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:53 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:17 CEST Tobias Imported from Hamamatsu datasheet.