RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2816032049 - Archived data from Mon, 30. August 2021 14:08:39 CEST


This is all the information about APD 2816032049. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2816032049
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C09
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.2 V
Dark current: 8.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 96
Position in Box: 5
EP1 batch: 90
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.8006268 V     T = -25 °C: 348.196268 V
Voltage for Gain 150: T = +20 °C: 391.5940746 V     T = -25 °C: 355.6043409 V
Voltage for Gain 200: T = +20 °C: 395.8953088 V     T = -25 °C: 359.7136977 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.687757229 V-1     T = -25 °C: 4.847750049 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.549603448 V-1     T = -25 °C: 9.969164602 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.99758045 V-1     T = -25 °C: 16.05534973 V-1
Break-through voltage: T = +20 °C: 411.4924531 V     T = -25 °C: 375.0767591 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:43:15 CEST oafedulidis Assigned to capsule by script
30. Aug 2021 14:08:39 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:00:42 CET jreher Updated box and position via API.
11. Aug 2020 17:59:23 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:19 CEST jreher Updated APD location via API.
28. Jan 2020 14:39:35 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:48 CET jreher Updated APD location via API.
27. Nov 2019 19:45:54 CET jreher Updated APD location via API.
25. Nov 2019 17:18:34 CET jreher Updated box and position via API.
20. Aug 2019 12:43:31 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:49:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:52 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:15 CEST Tobias Imported from Hamamatsu datasheet.