Show Hamamatsu Avalanche Photo Diode 2816032041 - Archived data from Fri, 29. November 2019 11:50:48 CET


This is all the information about APD 2816032041. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2816032041
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Giessen
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.6 V
Dark current: 9.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 95
Position in Box: 50
EP1 batch: 90
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:21:37 CET jreher Assigned to capsule by script
05. Feb 2021 11:00:39 CET jreher Updated box and position via API.
03. Feb 2021 18:26:08 CET jreher Updated box and position via API.
18. Dec 2020 13:59:42 CET jreher Updated box and position via API.
11. Aug 2020 17:46:32 CEST jreher Updated APD characteristics via API.
03. Dec 2019 15:02:24 CET jreher Updated APD location via API.
29. Nov 2019 11:50:48 CET jreher Updated APD location via API.
27. Nov 2019 19:45:47 CET jreher Updated APD location via API.
25. Nov 2019 17:18:32 CET jreher Updated box and position via API.
14. Nov 2019 17:30:43 CET spankonin Updated APD batch assignment via API.
20. Aug 2019 12:43:30 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:55 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:51 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:14 CEST Tobias Imported from Hamamatsu datasheet.