RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2815031955 - Archived data from Wed, 03. February 2021 18:25:58 CET


This is all the information about APD 2815031955. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2815031955
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 10 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 94
Position in Box: 34
EP1 batch: 87
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.0443086 V     T = -25 °C: 345.6471601 V
Voltage for Gain 150: T = +20 °C: 388.8599315 V     T = -25 °C: 352.9873335 V
Voltage for Gain 200: T = +20 °C: 393.2136368 V     T = -25 °C: 357.1098609 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.605209076 V-1     T = -25 °C: 4.680502293 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.144930516 V-1     T = -25 °C: 9.582078223 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.2172959 V-1     T = -25 °C: 15.16342735 V-1
Break-through voltage: T = +20 °C: 408.8558737 V     T = -25 °C: 372.3288032 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:22:09 CET jreher Assigned to capsule by script
05. Feb 2021 11:00:29 CET jreher Updated box and position via API.
03. Feb 2021 18:25:58 CET jreher Updated box and position via API.
18. Dec 2020 14:00:18 CET jreher Updated box and position via API.
11. Aug 2020 17:59:19 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:17 CEST jreher Updated APD location via API.
28. Jan 2020 14:39:33 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:43 CET jreher Updated APD location via API.
27. Nov 2019 19:45:34 CET jreher Updated APD location via API.
25. Nov 2019 17:18:26 CET jreher Updated box and position via API.
20. Aug 2019 12:35:29 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:46 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:49 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:12 CEST Tobias Imported from Hamamatsu datasheet.