RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2814031881 - Archived data from Fri, 18. December 2020 14:01:07 CET


This is all the information about APD 2814031881. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2814031881
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.5 V
Dark current: 8.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 94
Position in Box: 1
EP1 batch: 86
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.1232891 V     T = -25 °C: 343.9737034 V
Voltage for Gain 150: T = +20 °C: 386.9209448 V     T = -25 °C: 351.2623239 V
Voltage for Gain 200: T = +20 °C: 391.2754336 V     T = -25 °C: 355.3547658 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.61242458 V-1     T = -25 °C: 5.024678679 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.12427602 V-1     T = -25 °C: 9.384638032 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.21636592 V-1     T = -25 °C: 14.89881713 V-1
Break-through voltage: T = +20 °C: 406.8035899 V     T = -25 °C: 370.4678413 V
   
Notes:


Version history

Time Author Change comment
15. Feb 2021 15:39:32 CET jreher Assigned to capsule by script
05. Feb 2021 11:00:25 CET jreher Updated box and position via API.
03. Feb 2021 18:25:54 CET jreher Updated box and position via API.
18. Dec 2020 14:01:07 CET jreher Updated box and position via API.
11. Aug 2020 17:59:12 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:14 CEST jreher Updated APD location via API.
28. Jan 2020 14:36:55 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:40 CET jreher Updated APD location via API.
27. Nov 2019 19:45:32 CET jreher Updated APD location via API.
25. Nov 2019 17:18:24 CET jreher Updated box and position via API.
20. Aug 2019 12:35:04 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:44 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:48 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:10 CEST Tobias Imported from Hamamatsu datasheet.