RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2814031848 - Archived data from Tue, 16. February 2021 12:28:36 CET


This is all the information about APD 2814031848. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2814031848
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 9.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 93
Position in Box: 22
EP1 batch: 85
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.9800033 V     T = -25 °C: 344.6618332 V
Voltage for Gain 150: T = +20 °C: 387.7924459 V     T = -25 °C: 351.9537324 V
Voltage for Gain 200: T = +20 °C: 392.1480597 V     T = -25 °C: 356.0332994 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.647821369 V-1     T = -25 °C: 4.716386096 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.178207801 V-1     T = -25 °C: 9.646842792 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.33041632 V-1     T = -25 °C: 15.46920926 V-1
Break-through voltage: T = +20 °C: 407.9607252 V     T = -25 °C: 371.3516188 V
   
Notes:


Version history

Time Author Change comment
29. Apr 2021 17:05:43 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:36 CET jreher Updated box and position via API.
05. Feb 2021 11:00:20 CET jreher Updated box and position via API.
03. Feb 2021 18:25:48 CET jreher Updated box and position via API.
11. Aug 2020 17:59:07 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:11 CEST jreher Updated APD location via API.
28. Jan 2020 14:35:04 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:38 CET jreher Updated APD location via API.
27. Nov 2019 19:45:22 CET jreher Updated APD location via API.
25. Nov 2019 17:18:19 CET jreher Updated box and position via API.
20. Aug 2019 12:34:42 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:37 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:47 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:09 CEST Tobias Imported from Hamamatsu datasheet.