RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2814031847 - Archived data from Tue, 11. August 2020 17:59:07 CEST


This is all the information about APD 2814031847. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2814031847
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.8 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 93
Position in Box: 21
EP1 batch: 85
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.7344452 V     T = -25 °C: 345.1848413 V
Voltage for Gain 150: T = +20 °C: 388.5312647 V     T = -25 °C: 352.5259364 V
Voltage for Gain 200: T = +20 °C: 392.8639207 V     T = -25 °C: 356.6188519 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.743211669 V-1     T = -25 °C: 4.868897266 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.559041058 V-1     T = -25 °C: 9.04182433 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.92428954 V-1     T = -25 °C: 16.21503004 V-1
Break-through voltage: T = +20 °C: 408.3581554 V     T = -25 °C: 371.8518426 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:44:26 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:18 CEST jreher Updated box and position via API.
05. Feb 2021 11:00:20 CET jreher Updated box and position via API.
03. Feb 2021 18:25:48 CET jreher Updated box and position via API.
11. Aug 2020 17:59:07 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:11 CEST jreher Updated APD location via API.
28. Jan 2020 14:35:03 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:38 CET jreher Updated APD location via API.
27. Nov 2019 19:45:22 CET jreher Updated APD location via API.
25. Nov 2019 17:18:19 CET jreher Updated box and position via API.
20. Aug 2019 12:34:41 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:37 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:47 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:09 CEST Tobias Imported from Hamamatsu datasheet.