RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2811031637 - Archived data from Wed, 03. February 2021 18:25:30 CET


This is all the information about APD 2811031637. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2811031637
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E05
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.9 V
Dark current: 4.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 91
Position in Box: 4
EP1 batch: 82
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.1645814 V     T = -25 °C: 346.3135118 V
Voltage for Gain 150: T = +20 °C: 388.8932118 V     T = -25 °C: 353.4439628 V
Voltage for Gain 200: T = +20 °C: 393.245942 V     T = -25 °C: 357.3626917 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.512522883 V-1     T = -25 °C: 4.725443228 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.84862668 V-1     T = -25 °C: 11.17254193 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.25072473 V-1     T = -25 °C: 17.55593416 V-1
Break-through voltage: T = +20 °C: 408.6269522 V     T = -25 °C: 372.2098726 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:19:18 CET jreher Assigned to capsule by script
05. Feb 2021 11:00:02 CET jreher Updated box and position via API.
03. Feb 2021 18:25:30 CET jreher Updated box and position via API.
18. Dec 2020 14:01:34 CET jreher Updated box and position via API.
11. Aug 2020 18:04:36 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:55:00 CEST jreher Updated APD location via API.
17. Feb 2020 17:55:23 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:29 CET jreher Updated APD location via API.
27. Nov 2019 19:44:58 CET jreher Updated APD location via API.
25. Nov 2019 17:18:08 CET jreher Updated box and position via API.
20. Aug 2019 12:32:45 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:48:20 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:43 CET Tobias Corrected dark current unit.
20. Jun 2018 13:36:05 CEST Tobias Imported from Hamamatsu datasheet.