Show Hamamatsu Avalanche Photo Diode 2808031421 - Archived data from Thu, 25. July 2019 12:11:09 CEST
This is all the information about APD 2808031421. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2808031421 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum Box 88 |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | E09 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 382.6 V |
| Dark current: | 6.9 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 88 |
| Position in Box: | 7 |
| EP1 batch: | 77 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
| Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
| Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
| Break-through voltage: | T = +20 °C: none T = -25 °C: none |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 07. Feb 2022 10:46:02 CET | oafedulidis | Assigned to capsule by script |
| 17. May 2021 09:17:31 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:59:38 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:25:07 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:39:24 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:44:25 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:17:53 CET | jreher | Updated box and position via API. |
| 13. Sep 2019 10:30:22 CEST | jgrochowski | Updated APD batch assignment via API. |
| 04. Sep 2019 13:17:10 CEST | markus.moritz | |
| 25. Jul 2019 12:11:09 CEST | spankonin | Updated APD batch assignment via API. |
| 05. Jul 2019 13:47:56 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:13:38 CET | Tobias | Corrected dark current unit. |
| 20. Jun 2018 13:35:56 CEST | Tobias | Imported from Hamamatsu datasheet. |