RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2806031291 - Archived data from Fri, 05. February 2021 10:59:34 CET


This is all the information about APD 2806031291. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2806031291
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.9 V
Dark current: 9.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 87
Position in Box: 43
EP1 batch: 76
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5119616 V     T = -25 °C: 347.2086779 V
Voltage for Gain 150: T = +20 °C: 390.3361038 V     T = -25 °C: 354.620974 V
Voltage for Gain 200: T = +20 °C: 394.6788558 V     T = -25 °C: 358.7558741 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.442790177 V-1     T = -25 °C: 4.820641833 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.745886912 V-1     T = -25 °C: 9.900495616 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.22263023 V-1     T = -25 °C: 15.82331427 V-1
Break-through voltage: T = +20 °C: 409.4312247 V     T = -25 °C: 373.1992816 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:52:16 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:26:51 CET jreher Updated box and position via API.
05. Feb 2021 10:59:34 CET jreher Updated box and position via API.
03. Feb 2021 18:25:03 CET jreher Updated box and position via API.
11. Aug 2020 17:39:22 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:44:17 CET jreher Updated APD location via API.
25. Nov 2019 17:17:50 CET jreher Updated box and position via API.
13. Sep 2019 10:30:01 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:11:39 CEST markus.moritz
25. Jul 2019 12:11:25 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:50 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:38 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:06:18 CEST Tobias Imported from Hamamatsu datasheet.