Show Hamamatsu Avalanche Photo Diode 2806031262 - Archived data from Tue, 11. August 2020 17:39:19 CEST


This is all the information about APD 2806031262. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2806031262
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.4 V
Dark current: 7.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 87
Position in Box: 23
EP1 batch: 76
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.8627381 V     T = -25 °C: 343.6744291 V
Voltage for Gain 150: T = +20 °C: 386.7029258 V     T = -25 °C: 351.0075624 V
Voltage for Gain 200: T = +20 °C: 391.0678028 V     T = -25 °C: 355.1386912 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.689880799 V-1     T = -25 °C: 4.706978807 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.246697649 V-1     T = -25 °C: 9.487433149 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.27951934 V-1     T = -25 °C: 14.97221771 V-1
Break-through voltage: T = +20 °C: 407.0394696 V     T = -25 °C: 370.454357 V
   
Notes:


Version history

Time Author Change comment
20. Oct 2021 09:32:19 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:00:49 CEST jreher Updated box and position via API.
05. Feb 2021 10:59:32 CET jreher Updated box and position via API.
03. Feb 2021 18:25:01 CET jreher Updated box and position via API.
11. Aug 2020 17:39:19 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:44:15 CET jreher Updated APD location via API.
25. Nov 2019 17:17:49 CET jreher Updated box and position via API.
13. Sep 2019 10:29:59 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:50:31 CEST markus.moritz
25. Jul 2019 12:11:24 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:49 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:37 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:06:09 CEST Tobias Imported from Hamamatsu datasheet.