RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2804031105 - Archived data from Fri, 18. December 2020 14:00:05 CET


This is all the information about APD 2804031105. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2804031105
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.7 V
Dark current: 9.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 85
Position in Box: 46
EP1 batch: 74
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2072706 V     T = -25 °C: 344.7899805 V
Voltage for Gain 150: T = +20 °C: 388.0314158 V     T = -25 °C: 352.1554209 V
Voltage for Gain 200: T = +20 °C: 392.4043101 V     T = -25 °C: 356.2946543 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.552126037 V-1     T = -25 °C: 4.997530926 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.926294874 V-1     T = -25 °C: 9.322180822 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.5875274 V-1     T = -25 °C: 14.64480064 V-1
Break-through voltage: T = +20 °C: 407.9177409 V     T = -25 °C: 371.5035203 V
   
Notes:


Version history

Time Author Change comment
15. Feb 2021 15:38:52 CET jreher Assigned to capsule by script
05. Feb 2021 10:59:21 CET jreher Updated box and position via API.
03. Feb 2021 18:24:50 CET jreher Updated box and position via API.
18. Dec 2020 14:00:05 CET jreher Updated box and position via API.
11. Aug 2020 17:39:07 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:56 CET jreher Updated APD location via API.
25. Nov 2019 17:17:41 CET jreher Updated box and position via API.
13. Sep 2019 10:29:15 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:28:17 CEST markus.moritz
25. Jul 2019 12:12:00 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:36 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:34 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:40 CEST Tobias Imported from Hamamatsu datasheet.