Show Hamamatsu Avalanche Photo Diode 2804031064 - Archived data from Tue, 11. August 2020 17:39:04 CEST
This is all the information about APD 2804031064. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2804031064 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | F05 |
| Break-through voltage: | 402 V |
| Voltage for Gain 100 (T=+25°C): | 377.4 V |
| Dark current: | 9.5 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 60 |
| Position in Box: | 42 |
| EP1 batch: | 73 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 26. Aug 2019 |
| Sent for analysis after irradiation: | 28. Aug 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 31. Aug 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 31. Aug 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 377.2899554 V T = -25 °C: 342.4864215 V |
| Voltage for Gain 150: | T = +20 °C: 385.1108146 V T = -25 °C: 349.8085244 V |
| Voltage for Gain 200: | T = +20 °C: 389.4909097 V T = -25 °C: 353.9126193 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.564937028 V-1 T = -25 °C: 4.817659375 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.92125079 V-1 T = -25 °C: 9.788306587 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.60220473 V-1 T = -25 °C: 15.60913313 V-1 |
| Break-through voltage: | T = +20 °C: 404.4109222 V T = -25 °C: 369.4378696 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 26. Apr 2021 15:22:14 CEST | oafedulidis | Updated box and position via API. |
| 05. Feb 2021 10:59:19 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:24:49 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:39:04 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:43:55 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:17:40 CET | jreher | Updated box and position via API. |
| 13. Sep 2019 10:28:56 CEST | jgrochowski | Updated APD batch assignment via API. |
| 04. Sep 2019 13:23:36 CEST | markus.moritz | |
| 25. Jul 2019 12:12:16 CEST | spankonin | Updated APD batch assignment via API. |
| 05. Jul 2019 13:47:35 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:13:34 CET | Tobias | Corrected dark current unit. |
| 24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
| 18. May 2018 12:05:31 CEST | Tobias | Imported from Hamamatsu datasheet. |