RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2710030806 - Archived data from Tue, 11. August 2020 17:38:44 CEST


This is all the information about APD 2710030806. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2710030806
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.5 V
Dark current: 18.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 83
Position in Box: 18
EP1 batch: 70
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.4121355 V     T = -25 °C: 344.148892 V
Voltage for Gain 150: T = +20 °C: 387.2507582 V     T = -25 °C: 351.4844069 V
Voltage for Gain 200: T = +20 °C: 391.6280923 V     T = -25 °C: 355.5757376 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.47502694 V-1     T = -25 °C: 4.918435568 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.758956298 V-1     T = -25 °C: 9.118066565 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.18587832 V-1     T = -25 °C: 16.29377657 V-1
Break-through voltage: T = +20 °C: 407.5463532 V     T = -25 °C: 371.0278084 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 09:59:32 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:13 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:59:02 CET jreher Updated box and position via API.
03. Feb 2021 18:24:32 CET jreher Updated box and position via API.
11. Aug 2020 17:38:44 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:32 CET jreher Updated APD location via API.
25. Nov 2019 17:17:29 CET jreher Updated box and position via API.
10. Sep 2019 11:23:05 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 12:43:01 CEST markus.moritz
25. Jul 2019 12:12:59 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:30 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:46 CEST Tobias Imported from Hamamatsu datasheet.