Show Hamamatsu Avalanche Photo Diode 2710030802 - Archived data from Tue, 16. February 2021 12:25:55 CET
This is all the information about APD 2710030802. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 2710030802 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | C11 |
| Break-through voltage: | 411 V |
| Voltage for Gain 100 (T=+25°C): | 383.1 V |
| Dark current: | 13.4 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 83 |
| Position in Box: | 15 |
| EP1 batch: | 69 |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | none |
| Position in grid: | none |
| Arrival for irradiation: | 26. Aug 2019 |
| Sent for analysis after irradiation: | 02. Sep 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 28. Aug 2019 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 31. Aug 2019 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 383.4810808 V T = -25 °C: 347.8031422 V |
| Voltage for Gain 150: | T = +20 °C: 391.3321877 V T = -25 °C: 355.2126516 V |
| Voltage for Gain 200: | T = +20 °C: 395.6863722 V T = -25 °C: 359.3743072 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.445843231 V-1 T = -25 °C: 4.951857975 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.620036787 V-1 T = -25 °C: 9.244890101 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 15.02841023 V-1 T = -25 °C: 16.38472293 V-1 |
| Break-through voltage: | T = +20 °C: 410.3943693 V T = -25 °C: 373.8565848 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 15. Apr 2021 16:14:07 CEST | oafedulidis | Assigned to capsule by script |
| 16. Feb 2021 12:25:55 CET | jreher | Updated box and position via API. |
| 05. Feb 2021 10:59:01 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:24:31 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:38:43 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:43:32 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:17:29 CET | jreher | Updated box and position via API. |
| 10. Sep 2019 11:23:04 CEST | jgrochowski | Updated APD batch assignment via API. |
| 04. Sep 2019 12:32:14 CEST | markus.moritz | |
| 25. Jul 2019 12:13:16 CEST | spankonin | Updated APD batch assignment via API. |
| 05. Jul 2019 13:47:18 CEST | jreher | Updated APD location via API. |
| 03. Jan 2019 00:13:30 CET | Tobias | Corrected dark current unit. |
| 24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
| 18. May 2018 12:04:45 CEST | Tobias | Imported from Hamamatsu datasheet. |